Störung
Ursache
Wassermenge zu
• Mousseur verschmutzt
gering
• Sieb vor Magnetventil verschmutzt
• Sieb im Adapter verschmutzt
Automatische
• Sicherheitsabschaltung aktiv
Spülung
• Umgebungsbedingungen nicht geeignet
funktioniert nicht
GB
Safety notes
Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be
replaced by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The plug-in voltage supply is only suitable for indoor use.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
This device may be used by children over 8 years of
age, as well as persons with physical, sensory, or
mental disabilities or inadequate experience and
knowledge, if they are under supervision or were
instructed in the safe use of the device and understand the
resulting risks. Children must not play with the device.
Cleaning and user maintenance must not be carried out by
children without supervision.
Technical data
• Voltage supply:
• Power consumption:
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
• Reception range according to Novoflex Zebra XL Grey Card,
grey side, 8x10", landscape (7 - 20cm adjustable):
• Type of fitting protection:
Thermal disinfection possible.
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
100-240 V AC 50-60 Hz/6.75 V DC
Abhilfe
- Mousseur reinigen oder austauschen
- Sieb reinigen
- Sieb austauschen oder reinigen
- Objekt entfernen
- Umgebungsbedingungen mit Fernbedienung
(Sonderzubehör, Bestell-Nr.: 36 407) im Testmode
bei max. Reichweite überprüfen, LED darf nicht
leuchten.
Installation
Flush pipes thoroughly before and after
installation (observe EN 806)!
Open hot and cold water supply and check that
connections are watertight.
To protect the storage heater from excess pressure you
must install the flow regulating valve provided.
Filling the storage heater, see page 3.
Volume of water in storage heater will expand as it
is heated. Expansion water must drip out of the
mixer spout. This process is necessary and
normal.
The spout must not be fitted with any downstream
resistances in the form of aerators and compo-nents
reducing flow (e.g. restrictors) as these will result in
damage to the storage heater.
Operation and settings,
see technical product information 99.0438.xxx
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
approaching user.
Setting mode is automatically terminated after 3 minutes.
2.4 W
60 s
Replacement parts
See page 1 (* = special accessories)
1 s
12cm
Care
IP 59
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Disposal note
This category of device does not belong in the domestic
A
waste, but must be disposed of separately in
accordance with the relevant national regulations.
2
2500 V
Special accessories - The factory settings can be
100 °C
changed and special functions can be activated,
deactivated and set using the infrared remote control
(Prod. no. 36 407). The current Technical Product
Information for the remote control can be downloaded
from www.grohe.com/tpi/remote-control.