Descargar Imprimir esta página

ELICA EBS630SS Guía De Instalación, Uso Y Mantenimiento página 8

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical Connection
I WARNING
ELECTRICAL SHOCK HAZARD�
I WARNING
DISCONNECT POWER BEFORE SERVICING�
REPLACE ALL PARTS AND PANELS BEFORE OPERATING�
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK�
1
Disconnect power�
2
Remove terminal box cover�
3
Remove the knockout in the terminal box cover and install
a UL listed or CSA approved
4
Run home power supply cable through strain relief, into
terminal box�
A
B
C
E
D
A. Home power supply cable
B. UL listed or CSA approved strain
relief
C. Black wires
5
Use UL listed wire connectors and connect black wires (C)
together�
6
Use UL listed wire connectors and connect white wires (E)
together�
I WARNING
ELECTRICAL SHOCK HAZARD�
I WARNING
ELECTRICALLY GROUND BLOWER�
CONNECT GROUND WIRE TO GREEN AND YELLOW
GROUND WIRE IN TERMINAL BOX� FAILURE TO DO SO CAN
RESULT IN DEATH OR ELECTRICAL SHOCK�
7
Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box
using UL listed wire connectors�
8
Tighten strain relief screw�
9
Install terminal box cover�
10 Check that all light bulbs are secure in their sockets�
11 Reconnect power�
8
" strain relief�
1
2
F
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-green ground
wires
Install duct covers
• When using both upper and lower vent covers, push lower
cover down onto hood and lift upper cover to ceiling and
install with two mounting screws (4x8mm)�
NOTE: For vented installations, the upper vent cover may
be reversed to hide slots�
A
B
A. Upper vent cover
B. Lower vent cover
C. 4 x 8 mm screws
D. Bracket
NOTE: To prevent scratches, lay paper or a kitchen towel over
the edges of the lower flue duct to protect the surface�
C
D
C

Publicidad

loading

Este manual también es adecuado para:

Ebs636ss