The power light is off and
the unit is not heating up
The heating indicator is
on, but the temperature
does not rise
The power light is on but
the temperature is not
rising
The temperature
controller is operating
normally but the indicator
light is off
No power supply
The connection of the
electric heater is
loose
Temperature
controller defective
Defective light
Check the power supply
1. Attach the two clamps
between the electric heater
and the screw
2. Replace the electric
heater
Replace the temperature
controller
Replace the indicator light