Installer level – Overview
D
Setting level
INST.MENU → PV MODE →
PV MODE
INST.MENU → PV MODE → PRIORITY
PRIORITY
INST.MENU → DI SPLAY →
WATE R
AIR INLET
T_EV APOR
PV ECO
PV MAX
SHED DING
FAN CONTR.
INST.MENU → SET TINGS →
ANTI -BACT.
SHED DING
T°C MINI
FAN MODE
MAX. TIME
INST.MENU → RESE T PAR. →
RESE T PAR.
INST.MENU → COUN TERS →
COUN TERS
INST.MENU → LOCK ING →
LOCK ING
82
Values
Unit
Min.
Max.
Current value
Current value
℃
Current value
℃
Current value
℃
Current value
Current value
Current value
Current value
Current value
℃
60
70
Current value
℃
43
43
Current value
2
24
h
Current value
Current value
Current value
Increment, select, explanation
YES, no
YES: PV MODE has higher priority than frost
protection and eco mode; no: PV MODE has
lower priority than frost protection and eco mode
Only visible if PV MODE = YES
0: Contact opened; 1: Contact closed
Only visible if PV MODE = YES
0: Contact opened; 1: Contact closed
Only visible if PV MODE = no
0: Contact opened; 1: Contact closed
Only visible if PV MODE = no
0: Contact opened; 1: Contact closed
1 °C; YES, no; number of days
Only visible if PV MODE = no
0: Product out of operation during high tariff
1: Only heat pump in operation during high tariff
2: Heat pump and immersion heater in operation
during high tariff
43 °C; no
1 = Fan operates only when the heat pump is
running. The fan speed automatically adjusts to
the heat pump's requirements.
2 = Fan operates only when the heat pump is
running. The fan runs at maximum speed.
3: Fan is controlled by an external humidistat
If PV MODE = YES: Only 1 and 2 can be selec-
ted
no, Auto, number of hours
YES, no
No. 1: Heat pump start cycles
No. 2: Immersion heater start cycles
No. 3: Not used
No. 4: Compressor operating hours
no; Auto; Pro
Installation and maintenance instructions 8000015884_00
Factory
setting
no
YES
no
1
no
1
no
no
no