Step 6
Days between regenerations H-
We press the DOWN key again and H- appears (Days between Regenerations)
These are days that if there is no water consumption, after the days we have programmed,
a maintenance regeneration will be carried out.
By means of the "menu/confirmation" key, and with the help of the UP and DOWN keys,
mark the days you want, between 00 and 40. By default it is always 30 days.
Press "menu/confirmation" to confirm.
Step 7
External signal mode
Finally, when you press the DOWN key again, b-01 (External signal mode) will appear.
This position has two varieties:
b-01 – For auxiliary output programming for additional pump/electrovalve
connection during washing. Useful in installations with insufficient pressures or external by-
pass control (requires additional elements).
b-02 - Only for industrial equipment.
By means of the "menu/confirmation" key, and with the help of the UP and DOWN keys,
select option b-01. Press "menu/confirmation" to confirm.
To finish the process, simply press the DOWN key again.
The current time will appear. The screen will remain in Service, once the valve is
programmed, the screen will indicate approximately every 15 seconds: Current time,
regeneration time, Water volume until the next regeneration and the instantaneous flow
rate.
Setting parameters
(Only to modify in factory or SAT of Official Agent).
Measurement unit configuration: HU-
To access this parameter, unplug it and plug it back in, then keep the DOWN +
REGENERATION keys pressed at the same time.
Press the DOWN key again, so that HU-, capacity format change, will appear.
HU-01 Cubic meters. (DO NOT CHANGE)
HU-02 Gallons.
It can be modified by pressing the "menu/confirmation" key, and then adjusting it using the
UP and DOWN keys, to the desired value.
Press "menu/confirmation" to confirm. Press the DOWN key and the programmed volume
to be treated will appear.