Before intervening in the softener, please check the following information:
PROBLEM DETAILS
Control valve not
working
Wrong regeneration time
Leak
Noise
High outlet water
hardness
Brine fault or insufficient
(does not draw brine)
Brine tank overflow
No softened water after
regeneration
Backwash flow rate too
high or too low
Salt water
Drain drains
continuously
11. TROUBLESHOOTING
CAUSE
1. Power plug not connected
2. Plug failure
3. Blackout
4. Damaged transformer
1. Time of day not set correctly
2. Power off more than 3 days
3. Bad contact
1. Loose connector
2. Broken o-ring
Air in the device
1. Poor inlet water quality
2. Very long regeneration period
3. By-pass valve open
4. Does not regenerate
1. Low inlet pressure
2.Brine pipe blocked
3. Broken injector
4. Air leak in brine tube
5. No salt
1. Too much recharge time
2. Lots of water after brine
1. Control circuit damaged
2. Low inlet pressure
3. Brine tank without salt
4. Clogged injector
5. Broken tube o-ring
1. No flow control in drain
2. Foreign material in drain flow control
1. Low inlet pressure
2. DLFC or drain pipe blocked
3. Excessive amount of saturated salt in
the brine tank
4. Very short fast wash
1.Lock-up control valve not reset
2. Control valve leak
3.Foreign material trapped in control valve
SOLUTION
1. Connect to network
2. Repair or replace plug
3. Check circuit and power supply
4. Replace transformer
Set the time
1. Connect or tighten the thread
2. Replace the o-ring
Backwash, release air
1. Contact supplier
2. Shorten regeneration cycle
3.Close by-pass valve
4. Check that the counter cable is connected.
1. Increase inlet pressure, above 2.5 bar
2. Check and remove obstruction
3. Replace injector
4. Check tube components, eliminate leak
5. Put salt
1. Shorten brine recharge time
2. Check brine suction and slow washing
1. Replace circuit
2. Increase inlet pressure
3. Add salt and regenerate manually
4. Disassemble injector, clean and reassemble
5. Replace o-ring
1. Install flow control in drain
2. Clean foreign material
1. Install pressure pump
2. Remove clogging
3. Decrease amount of filling water
4. Extend fast washing time
1.Set position to service
2. Replace control valve
3.Remove foreign material
INSTRUCTION MANUAL
EN
|
73

Publicidad

loading

Productos relacionados para Bbagua Ceramic PILOT 2.0

Este manual también es adecuado para:

Ceramic pilot 2.5