Descargar Imprimir esta página

Truper MUT-39 Instructivo página 23

Publicidad

Idiomas disponibles

Idiomas disponibles

REAL RMS AC VOLTAGE
Range
2 V
20 V
200 V
750 V
Input resistance: 10 M
Overload protection: 1 000 V DC or AC at peak value
Maximum frequency response value: (40 – 1 000) Hz
(for standard sine wave and triangle wave)
Display: True RMS (only as reference, when over 200 Hz in other waves)
In the AC 750 V range, AC 380 V and AC 220 V commercial power can be
tested, press the "HOLD" key to display the frequency of the commercial
power
DC CURRENT
Range
2 mA
20 mA
200 mA
20 A
Overload protection: 250 V DC or AC at peak value
The use of automatic recovery fuses after the external fault disappears,
the fuse is returned to normal and the multimeter can be used normally.
Maximum voltage drop measurement: 200 mV
Maximum input current: 20 A (Test time must be between 10 seconds)
Frequency response: 40 – 1 000 Hz (For sine and standard wave and
triangle wave)
Display: True RMS (Only as reference when over 200 Hz in other waves.
Resolution
1 mV
10 mV
100 mV
1 V
Resolution
1 µA
10 µA
100 µA
10 mA
Accuracy
(1,0% de rdg + 8 dgts)
(1,2% de rdg + 8 dgts)
Accuracy
(1,2% of rdg + 8 dgts)
(1,2% of rdg + 8 dgts)