6.3.
Electric Power Supply Connection
Connection must be carried out by authorised and
qualified
staff,
regarding the subject and using appropriate
prescribed material.
Before connecting the appliance to the
electric mains, check that the voltage and the
frequency correspond to the data stated on the
GB
registration plate applied on the rear of the
appliance.
The equipment is supplied with one of the
following operating voltages:
230V 1~ 50Hz
220V1~ 60Hz.
!
Provide an earthed socket with a capacity
appropriate to the absorption indicated on the
identification plate.
!
It is forbidden to operate the equipment
connected to an ungrounded system.
!
For direct connection to the power supply, a
device must be provided to ensure disconnection
from the power supply, with a contact-opening
distance allowing complete disconnection under
the conditions of overvoltage category III, in
accordance with the installation rules.
Refer to the technical data on the
identification plate for the correct sizing of the
switch.
6.4.
Inspection
The appliance is delivered in conditions such that
it can be started-up by the user.
This functionality is guaranteed by passing the
tests (electric inspection - functional inspection,
appearance inspection) and relative certification
through the specific attachments.
At least the following should be checked after
installation:
7.
USE AND FUNCTIONING
7.1.
Description of the Functioning Cycles
ENGLISH
respecting
the
current
The switch-disconnector must be located
laws
close to the equipment, must be visible to the
operator and must be indicated by an information
sign.
!
If a plug is used, it must comply with national
installation regulations.
!
The plug must be accessible even after the
equipment has been placed in the installation
location.
The plug must always be visible to the
operator performing the maintenance operation.
After the electrical connection, check that the
supply voltage, when the equipment is running,
does not deviate from the nominal value given on
the specifications plate ±10%.
The power cable used for connection to the mains
supply is of type H05VV-F; when replacing it, use
a cable with the same or better characteristics.
!
When replacing the power cable, the earth
conductor must be kept longer than the active
conductors.
!
The replacement of a damaged power cable
must be done by a qualified technician in order to
prevent any possible risk.
 Check the electric connections.
 Check the functionality and efficiency of
drains.
 Check that there are no tools or materials left
in the appliance that could jeopardise its
functionality or even damage the machine.
 Have the appliance perform at least one
complete chill blasting/shock freezing cycle
12