INSTALLATION
WARNING: The optional blower is equipped with a three-prong (grounding) plug for
your protection against shock hazard and must be plugged directly into a properly
grounded three-prong receptacle.
The heater must be disconnected from gas supply before installing the blower.
Contact a qualified service person to do this.
BLOWER INSTALLATION (OPTIONAL)
The blower is to be installed at the rear of the
stove, on the rear heat shield. Align the blower
and gasket mounting holes with those on the rear
heat shield.
VENT-FREE BLOWER INFORMATION
This blower is a rotary tangential fan. It is
designed to direct heated air radiating from the
rear of the stove to the front at a low velocity. DO
NOT expect a large volume of air to be felt when
standing in front of the stove.
The blower is NOT thermostatically controlled. The blower speed is manually controlled with variable
speeds, which are selected by rotating the speed control knob clockwise. When routing the power
cord, be sure that the cord does not come into contact with any hot surface. Operating Voltage is 110
to 120 VAC at 60 Cycle.
IMPORTANT: Ensure the blower and gasket are oriented correctly. The blower wheel
and gasket cut-out must align with the cut-out in the rear heat shield. Fasten the
blower and gasket to the rear heat shield using the four (4) screws provided. DO
NOT over tighten screws. Be sure to plug the blower into a 3 prong gounded outlet.
DO NOT tamper with the grounding prong on the cord.
WARNING: DO NOT submerge the blower into any liquids. This will create an
electric shock hazard. Disconnect power before installing or servicing unit.
CAUTION: Extreme caution is necessary when any fan is used by or near
children or invalids and whenever the fan is left operating unattended.
CLEANING
Periodic cleaning of the blower is recommended. Dust or dirt accumulation could significantly restrict
airflow. Restriction in airflow will reduce the efficiency of the blower and possibly damage the motor.
Back of Stove
Gasket
Blower
Screws
Speed Control Knob
12
Knock-Out Panel
Remove Prior to
Blower Installation
Electrical Cord
120V AC