● The appliance should be installed indoor. It is not allowed to install the appliance outdoor or in the
humid places.
● If the appliance is installed in the place vulnerable to rain, it is essential to take the necessary
water-resistant measures to prevent rain entering into the internal components, otherwise the
components may be eroded easily and cause physical danger.
● The appliance must be installed on a solid wall. In order to drain condensate water from evaporate
smoothly, the inclination angle to the floor should no more than 5°.
● Select a place where there has good ventilation and the air outlet should avoid facing the wind
direction. There should be no obstacles at the air inlet and air outlet.
● Select a place where water pipes and electric power can be easily connected.
● Select a place where water drained out of the relief valve will not splash on the wood floor or
furniture.
● Reserve space for installation and maintenance shown as Fig.4.
3. Air Duct Connection
The appliance is designed to connect to the duct. In case the appliance connected with duct, the
diameter of the duct must ≥150 mm. The total length should not exceed the maximum length of 3m,
typically using flexible plastic duct.
When connect duct, portion air flow will lose in the system, which will lead to capacity decreased
in the system.
● Example 1.
The appliance installed in garage/outhouse can refresh air. Inlet air from internal duct, outlet air
ducted to outdoor. Total length≤3m.
● Example 2.
The appliance installed in utility room can dehumidify air and dry clothes effectively. Inlet air from
room without duct, outlet air ducted to outdoor. Air outlet duct length≤3m.
Fig.5 Installation and fixation
9