Troubleshooting:
Example, Error 001: blocked support for foil reception in the travel path downwards (motor switches off).
GB
Error
Error 002: Disorder protection shield, microswitch
not reached or actuated
Error 003: Microswitch for form pot not operated
Error 004: Heating position switch not reached
Error 010: Program abort (timeout foil reception)
Error 011: Program abort (timeout form pot)
Error 021: Disorder of the temperature
measurement
Only Track
-P-ci
®
Error 031: Runtime of compressor too long
30
Move support for foil reception step by step downwards (motor
down) or upwards (motor up) in the respective end position.
(Press touch fields repeatedly)
Example: red light up, position switch is switched on.
Possible cause
The support for the foil reception has not moved
down the red protection shield.
Form pot position changed during thermoforming/
switch defective.
When the support for foil reception is raised, the
heating position switch is not reached/switch
defective.
Foil reception was not in heating position for
more than 10 sec. during heating.
The form pot was not in thermoforming position for
more than 10 sec. at the end of the heating time.
Heater was in operation for more than
10 min. / IR temperature sensor defective.
Compressor needs longer than 90 seconds to build
enough pressure, pressure system leaking.
Possible elimination
Make sure that the foil reception is snapped into
place, push it completely into the unit.
Do not pull out the form pot during the thermo-
forming process.
See Error 001, »Heating switch« must light up.
The foil reception must be pulled out only briefly
and must be pushed back into place within
10 seconds.
The form pot must be in the rearmost, locked posi-
tion for the thermoforming process. If not,
the program is aborted after 10 sec.
After 10 minutes of heating, the heater switches
off for safety reasons.
Check compressed air system.