K200_400.book Seite 13 Mittwoch, 6. Mai 2009 7:48 07
Operating Controls
1 ON/OFF switch
2 Pressure lead
3 Compressor unit
4 Suction filter
5 Manual motor protection
6 Relief valve
7 Pressure switch
8 Handle
9 Oil filler opening
10 Oil drain plug
11 Air escape cock
12 Manometer for working pressure
13 Safety valve
14 Manometer for reservoir pressure
15 Non-return valve
16 Reservoir
17 Vibration damper
18 Condensation water drain cock
19 Wheels
20 Pressure reducer
Not all of the accessories illustrated or described are in-
cluded as standard delivery.
Use as Intended
The machine is designed for generating compressed
atmospheric air for commercial and industrial pur-
poses, i. e. for use as working air for driving tools,
as blowing air, e.g. for painting, or as control air for
plants and equipment.
For damage caused by usage other then intended,
the user is responsible.
Equipment Protection
– The intake air must be free from any aggressive
or inflammable particles.
– Before each operation, check the oil level using
the oil dip stick and, if necessary, replenish.
– Extension cables of up to 25 m in length must
have a cross-section of 1.5 mm
yond this require 2.5 mm
the conductor is too small, this will cause a volt-
age drop and there is no guarantee that the mo-
tor will start correctly. Cable reels must be fully
unwound.
– Never pull out the mains plug while the motor is
running. If the mains voltage fails, switch the ma-
chine off using the On/Off switch 1 and when
the voltage has been restored, switch on again.
– Do not exceed the maximum delivery output of
the machine (20 switchings per hour). At over-
load the pressure switch 7 is actuated. The ma-
chine is utilised optimally with a pause/operation
time ratio of 1 : 3.
Compressor Function
The Würth machines of model series K 200, K 280
and K 400 are compressors with drive motors flang-
ed directly onto the compressor. Fresh air is drawn
in via the intake filter 4 serving as a sound absorber,
and compressed in the cylinder. The compressor
valve integrated in the cylinder head controls the
suction and emission of the air. The compressed air
flows into the compressed air reservoir via the pres-
sure lead 2 and the non-return valve 15.
The compressor functions in intermittent operation.
Upon reaching the maximum pressure the pressure
switch 7 switches the compressor off and when the
pressure falls to approx. 8 bar (for the K 200 ap-
prox. 6 bar) switches it on again.