K200_400.book Seite 15 Mittwoch, 6. Mai 2009 7:48 07
Maintenance and Cleaning
Before commencing any work on the machi-
ne, discharge the air from the reservoir and
switch the machine off.
Always keep the machine clean.
Suction filter 4
– Change the foamed-plastic or paper-filter insert
when dirty.
– Wash out the wire-gauze filter insert in wash oil
and then dry, re-lubricate and re-use.
Draining the condensation
– Caution! The compressed air reservoir 16 is un-
der pressure. Place a collecting vessel under-
neath. Carefully open the condensation water
drain cock 18 on the base of the compressed air
reservoir by making a 1/2 turn and drain the
condensation.
– Check the condensation level regularly in the
transparent container of the pressure reducer 20.
It must not exceed the upper marking. For drain-
ing the condensation, the knob located on the un-
derside of the pressure reducer must be opened
a 1/2 turn under pressure.
Oil change
– As a basic rule the oil change should be carried
out under hot-running conditions.
– Place the collecting vessel underneath and open
the oil drain plug 10. Caution! Danger of burn-
ing from the hot oil!
– Close the oil drain plug 10 and fill up with oil of
class ISO 100 through the oil filler opening 9.
Maintenance intervals
Care
- change the cooling fins
Screwing connections
- tighten once after 50
Checking the oil level
- daily, or before each
Changing the oil
-for the first time after 5
- regularly after 100
Draining the
- at least weekly
condensation
- if required, daily
Checking the intake
- weekly
filter
Cleaning the intake
- monthly, and more
filter
Changing the intake
- if extremely dirty or
filter
Cleaning the non-return
- every 2 years
valve
Recommended check
-
according to pressure
reservoir instructions
-
If the machine should happen to fail despite the care
taken in manufacture and testing, repair should be
carried out by an authorised customer services
agent for Würth power tools.
For all correspondence and spare parts orders, al-
ways include the 6 digit order number of the ma-
chine!
of the cylinder and
pressure lead 2
regularly; clean the
manometer sight
glasses
hours of operation
use
hours of operation
hours of operation,
however, at least once
every 6 months
often if exposed to
large amounts of dust
damaged
Warning! discharge the
reservoir pressure!
every 5 years - internal
check
every 10 years -
pressure check
15