Table 2: Meaning of the color display
Outputs
Color
OUT
Green
Red
OUT invert
Green
Red
3.6 Diagnosis
3.6.1 "Diagnosis" menu item
In the Diagnosis menu item, parameters for the diagnosis are set.
Parameters
Submenu 1
Submenu 2
Status
Peak
The Peak submenu item contains settings and information on pres-
sure peaks.
Peak Count
Peak Thrsh.
Reset Peaks
Log
The Log submenu item contains all available log functions.
MIN Value
MAX Value
Reset Log
Count
The Count submenu item contains all available counters.
Switchings
Load change
Operation
Start-Ups
4 Technical data
For technical specifications, see the assembly instructions and the product page
at the Emerson Store.
AVENTICS™ PE7 | R412028763-BAL-001-AA | English
Meaning
Output switched
Output not switched
Output not switched
Output switched
Value range / op-
Meaning
tions
Device is OK
Product operates
properly
Maintenance required Maintenance required
Out of specification
Parameters outside
range of validity
Functional check
Measured value or
load outside range of
validity
Failure
Hardware failure, re-
placement required
1 ... 2 147 483 647
Counts how often the
pressure exceeds the
value of Peak Thrsh.
Nominal pressure
Threshold at which
range of sensor
the Peak Count
counter is triggered
Reset function
Reset Peak Count to 0
Technically measur-
Stores the lowest
able range
pressure value
Technically measur-
Stores the highest
able range
pressure value
Reset function
Reset MIN Value and
MAX Value
1 ... 2 147 483 647
Counts the switching
state changes at Out1
and Out2 separately
1 ... 2 147 483 647
Counts the pressure
load changes
Only when the direc-
tion is reversed by
> 20 %, the algorithm
counts up.
1 ... 2 147 483 647
Operating hours
counter
Switch-on times of
less than 60 minutes
are not added.
1 ... 2 147 483 647
Counts the start-up
operations
9