Statistics
View
LastReset
(read only)
Reset
Fig. 16
Counter
Objective
Submenu
View the counter
Reset the counter
Reset
Counter
Mass (read only)
Volume (read only)
Energy (read only)
LastReset
(read only)
Reset
Fig. 17
System
Objective
Submenu
Service login
Service
Reset to factory settings
FactReset
Serial Number (read only)
SerialNumber
Set the device tag
DevTag
Set the Application tag
AppTag
FWVersion (read only)
FWVersion
Calibration (read only)
Calibration
BLVersion (read only)
BLVersion
HWVersion (read only)
HWVersion
AVENTICS™ 652/653 | 549411-001-AB | English
max, mean, min values:
MassFlowRate
Pressure
Temperature
VolumetricFlowRate
FlowVelocity
abort
store
(action required)
abort
store
Option
Select from the Mass, Volume, En-
ergy, and LastReset submenus and
view the counter
Reset the counter
(action required)
abort
store
Option
Perform a service login for au-
thorized users
Reset the system to the fac-
tory settings
View the part number (serial
number)
Set the device tag
Set the Application tag
View the firmware version
View the firmware defaults
View the bootload version
View the hardware version
System
Service
FactReset
SerialNumber
(read only)
DevTag
AppTag
FWVersion
(read only)
Calibration
(read only)
BLVersion
(read only)
HWVersion
(read only)
Fig. 18
11.3 Settings for the IO-Link variant
The settings apply to all variants of the product with IO-Link electrical connec-
tion.
The display shows the measured value menu with the default setting (kg/h, m/s).
Objective
Menu
Select menu
Standard screen
Set the switch output
Q1 Menu
Set the switch output
Q2 Menu
Set the analog output
Qa Menu
Q1 Menu
The Q1 menu contains the settings for switch output 1.
Objective
Submenu
Set the hysteresis or window
Mode
function
Set the switching point
SetPoint1
Set the resetting point/hys-
SetPoint2
teresis or lower window limit
Set the switching characteris-
Polarity
tics of the break contact
Simulate the switch output
Simulate
Set PNP/NPN or push/pull
DriverType
(DRV)
#_#_#_#
abort
store
(action required)
abort
store
###
abort
store
###
abort
store
Option
Press and hold any arrow but-
ton for at least 2 seconds and
select between Q1 Menu,
Q2 Menu, and Qa Menu.
Set the switch output
Set the switch output
Set the analog output
Option
Set the mode for hysteresis or
window function with the as-
sociated measurement pa-
rameters
Set the switching point
Set the resetting point/hys-
teresis or lower window limit
Select between Normally-
Closed and NormallyOpen
Select Active, Inactive, or Nor-
mal (measuring operation)
Set to PNP/NPN or push/pull
(DRV)
28