30 |
INSTRUCTION MANUAL
ATTENTION!
The figures mentioned in the chapters "GENERAL WARNINGS", "GAS MODEL INSTRUCTIONS" and "ELECTRIC
MODEL INSTRUCTIONS" are shown on the initial pages of this manual.
UNIT DESCRIPTION
Sturdy steel structure with 4 adjustable feet. External
chrome-nickel steel layer. Pressed tanks with large
rounded borders completely made from AISI 316 stainless
steel. High performances ensured by the Incoloy stainless
steel heating elements positioned directly inside the tank
for the pasta cookers and outside the tank for bain-marie
EN
units.
Before beginning the installation, remove the packaging.
A few parts are protected with an adhesive film, which
should be removed carefully. Remove any glue residual
with the proper substances, such as petrol; never use
abrasive substances. Mount the unit feet; the unit must
be levelled; small differences of height can be solved by
adjusting the feet. In the Top versions, make sure that the
bench or the cabinet you have chosen can bear the unit.
The main switch or the socket must be close to the unit
and easy to reach. We recommend placing the unit under a
suction hood so that vapour can quickly evacuate. "During
installation, check if the appliance has a plate meaning
it must be fixed and installed in a fixed position. In this
case use the supplied stabilization device and install the
appliance at more than 50 cm from the back or side walls.
Those appliances which do not have this plate can be
positioned without being fixed at the distance specified
above" (see Fig. 1).
Attention!
For the Top versions, pay attention to the unit's distance
from the external border of the top (Fig. 6).
Room ventilation
The room where the appliance is installed must be fitted
with air intakes to guarantee the correct operation of the
unit and air exchange. The air intakes must be of adequate
dimensions, be protected by grids and positioned free of
any obstruction. (See Fig. 2 – Fig. 3).
Caution - Warning
Do not install the appliance near any other units that
can reach high temperatures: the electrical components
might be damaged. During installation, make sure that
INSTALLATION
MOD.
N°:
Qn
V
kW:
Hz: 50/60
the air suctions and the evacuation ways are free of any
obstacles.
INSTALLATION
The installation, start-up and maintenance of the unit must
be performed by qualified personnel.
All installation operations must be carried out in conformity
with the regulations in force.
The manufacturer declines all responsibility for improper
operations due to the incorrect or improper installation.
Warning!
Before performing any operation, cut off the main
power supply.
For a direct network connection, it is necessary to
provide a device that ensures the disconnection
from the network with an opening distance from the
contacts that allows for a complete disconnection
under the conditions of overvoltage category III, in
accordance to the rules of installation.
For the LX models, the power supply cable can be
connected/replaced after installing the unit. On the unit
back, there is a compartment that the technician can
reach easily to perform the connection operations.
Attention!
Never interrupt the yellow-green ground cable.
ELECTRICAL CONNECTION
To prevent any risk, replace the power supply cable if it is
damaged. The cable must be replaced by the manufacturer
or by its technical assistance or by a qualified technician.
Connect the unit to the mains, following the provided
instructions (see Fig.4 – Fig.5):
1) Install, if not present, a disconnecting switch (A) close
to the appliance with a thermal magnetic release and
differential locking.
2) Open the doors (B), if present, and loosen the screws
(C) to disassemble the panel (D). (In the E6CP6B and
E6CP6M models, the terminal board is positioned on
the rear side. Remove the back to reach it.)
IPX