Descargar Imprimir esta página

Siemens SPCP332 Manual De Instrucciones página 3

Ocultar thumbs Ver también para SPCP332:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 4
Back tamper switch installation
The back tamper switch (Fig.1 item 26) is required
for SSF Larmklass 2 and EN Alarm Grade 3.
The back tamper switch is delivered with SPCP333
or is available as an optional extra (SPCY130).
Mounting the wall fixing plate
Mount the SPC enclosure in the appropriate
position on the wall using all three fixings (see
Fig. 8 item 1).
Draw a line around the inside of the back
tamper cutout (see Fig. 8 item 2) to provide a
guide for the wall plate on the fixing wall.
Remove the enclosure from the wall.
Place the wall plate (Fig 9, item 1) on the wall
centring it precisely around the rectangle
previously drawn (Fig. 9, item 2).
Ensure all four flanges on the wall plate are
flush with the wall.
Mark the four fixings on the wall plate.
Drill and use suitable screws (max. 4 mm) for
the wall substrate.
Fit the wall plate to the wall.
Fitting the back tamper switch
Insert the tamper switch (Fig. 10 item 2) into
the back of the enclosure so that the plunger
faces outwards. (Fig. 10 item 1)
Fit the enclosure back onto the wall using the
three fixings previously removed.
Visually check to ensure there is a flush finish
between the wall plate and the enclosure
metalwork.
WARNING:
If the wall fixing plate is not accurately aligned then
the enclosure will not sit properly on its fixings.
Wiring the back tamper switch
Connect one end of the tamper leads to
terminal block CN4 (Fig.1 item 25).
Plug the two connectors at the other ends of
the leads onto the COM (common) and NO
(normally open) spade connectors on the back
tamper switch.
Appendix A: LED Status
Mains
Battery
Condition
green
green
Normal
On
On
Mains OK,
battery
On
Flash
charging
Mains fail,
Off
On
battery OK
Mains OK,
and battery
On
Off
not installed
or faulty.
Mains fail,
and battery
not installed,
faulty or in
All LEDs off
deep
discharge
protection
mode.
Output 1 fuse
open
Output 2 fuse
open
Expander
fuse open
More than
one fuse open
Current
exceeded on
any output
PSU switcher
Off
failure
Battery link missing
All LEDs flash together
* Current limit
Appendix B: Battery link position (Fig. 1,
item 8)
Link
Description
DTX
Do not use.
Select this option if a 17Ah battery is fitted to
17 Ah
the PSU
Select this option if a 7Ah battery is fitted to
7 Ah
the PSU.
Note: Only one of the above links can be fitted to
this header.
ppendix C: Choosing the stand-by battery
A
The table below shows the maximum total current
(in mA) that can be drawn from all outputs for EN
compliance. Note that other limits apply, for
example, the maximum current that can be drawn
from each of outputs 1 and 2 is 750 mA.
Available current in mA =
1000 * (0.85 * battery capacity in Ah) / (standby
time in hours) - 77 mA
Standby
Time
(hours)
Appendix D: Fitting additional expanders in
the SPC hinged enclosure
The enclosure can accommodate:
• 1 x Battery (17 Ah max.)
• 1 x PSU Expander (SPCP330)
• 3 x I/O Expanders (optional)
To access the expanders and the PSU, open the
front lid to view the hinged mounting bracket. The
boards are secured to the hinged mounting bracket
by four mounting pillars.
To access or install a PSU in this enclosure:
With an appropriate screwdriver, loosen (but do
not remove) the top two securing screws on the
mounting bracket.
Gently push the mounting bracket in an upward
direction until the screws are free from contact
with the bracket.
*
Fuse
Limit
Status
Slowly but firmly pull the mounting bracket out
red
red
green
until it rotates down and is secured by the
Off
Off
On
resting pins
The underside of the mounting bracket and the
On
enclosure provides space for additional
expanders to be installed (secured by four
mounting pillars).
On
The PSU is secured to the front of the enclosure by
mounting pillars.
On
See Fig. 6: Mounted PSU
1 Battery
Please ensure that battery flaps are used to
hold the battery securely when mounted in
the cabinet.
See Fig. 7: Rotated views
1 Battery
2 Expanders
3 SPC controller or PSU
Single
On
Flash
Double
When installing the SPCP330 (PSU and
On
Flash
Expander), ensure that the 4-pin cable is
Triple
securely attached to the connector on the
On
Flash
expander and to the PSU beneath.
On
On
On
On
Flash
Battery Capacity
7 Ah
17 Ah
(Grade 2)
(Grade 3)
12
419
1127
24
171
525
30
121
405
60
Not to be used
164
Technical data
Power supply
Type A (EN50131-1)
Mains voltage
230 V AC, +10 to -15 %, 50 Hz
500 mA T (replacable part on mains
Mains fuse
terminal block)
Power
Max. 220 mA at 230 V AC
consumption
Operating
Max. 117 mA at 12 V DC (all relays
Current
activated)
Quiescent
Max. 77 mA at 12 V DC
Current
11-14 V DC in normal conditions
(mains powered and fully charged
battery), min. 9.5 V DC when powered
Output Voltage
by secondary device (before system
shut down to battery deep discharge
protection)
Low voltage
7.5 V DC
trigger
Over voltage
15 V DC
protection
Peak to Peak
Max. 5% of output voltage
ripple
Auxiliary power
Max. 1500 mA at 12 V DC (750 mA
(nominal)
per output)
SPCP332: YUASA NP7-12FR (7 Ah)
SPCP333: YUASA NP17-12FR
Battery type
(17 Ah)
(battery not supplied with product)
SPCP332: 72h for 80 % of battery
capacity
Battery charger
SPCP333: 24h for 80 % of battery
capacity
Current limited to 2 A (fuse protected),
Battery
deep discharge protection at 10.5 V
protection
DC +/- 3 % (fault at deep discharge
voltage + 0.5 V DC)
Number of on-
8
board zones
Dual 4K7 (default), other resistor
EOL resistor
combinations configurable
Number of on-
2 (single-pole changeover, 30 V DC /
board relays
max. 1 A resistive switching current)
Field bus
X-BUS on RS-485 (307 kb/s)
No calibration checks required
Calibration
(calibrated at manufacturing)
Serviceable
No serviceable parts available
parts
SPCP332: Front spring tamper, back
tamper
Tamper contact
SPCP333: Front spring tamper
Operating
0 to +40 °C
temperature
Relative
Max. 90 % (non-condensing)
humidity
Colour
RAL 9003 (signal white)
SPCP332: 264 x 357 x 81 mm
Dimensions
(W x H x D)
SPCP333: 326 x 415 x 114 mm
SPCP332: 4.7 kg
Weight
SPCP333: 6.3 kg
SPCP332: Small metal housing (>1.2
mm mild steel)
Housing
SPCP333: Hinged metal housing
(>1.2 mm mild steel)
Housing can
SPCP333: 3 additional expanders
contain up to
(size 150 x 82 mm)
Environmental
Class II Indoor General
Class
Standards
SPCP332
Certified according:
EN50131-1:2006 (Grade 2, Class II
Indoor General),
TS50131-3:2003 (Grade 2),
EN50131-6:2008 (Grade 2),
SSF 1014 ed.3:2005 (Larmklass 1)
SPCP333
EN50131-1:2006 (Grade 3, Class II
Indoor General),
TS50131-3:2003 (Grade 3),
EN50131-6:2008 (Grade 3),
SSF 1014 ed.3:2005 (Larmklass 2)

Publicidad

loading

Este manual también es adecuado para:

Spcp333