1. Install the Controller
CAUTION: Risk of product damage. The controller is rated to operate in temperatures up to 104°F
(40°C). Do not install near heat sources (such as radiators or under whirlpool surrounds) or in any location
where the temperature may exceed 104°F (40°C).
IMPORTANT! The controller must be placed in a dry area, separate from any digital valve location.
NOTE: The controller comes equipped with rubber feet for placement on a shelf, or it can be installed to a
vertical surface using the mounting holes.
The controller is designed to fit within a 2x4 stud cavity. The cavity must be free of insulation.
If mounting within a stud cavity, an access panel must be provided for servicing.
Installation In a Stud Cavity
Install a vertical surface between the studs.
Install four drywall screws according to the dimensions above. The screws should protrude 5/16" (8
mm).
Install a 120 V electrical outlet within the stud framing, in close proximity to the controller. A GFCI
outlet may be required in certain applications.
NOTE: The power supply should be placed on a horizontal surface. Do not secure the power supply to
any surface.
Install a horizontal board to accommodate the power supply. Ensure the cord can be routed to the
electrical outlet without being pinched.
Remove the rubber feet from the bottom of the controller.
Hook the controller onto the protruding screws.
Route the power supply from the controller to the electrical outlet.