Descargar Imprimir esta página

hafele WT 400 Manual De Instrucciones página 73

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 182
3.3 Technical data WRU 400 / WRU 410
Feature
Power supply
Current consumption max. (12 V)
Power consumption max.
Ambient temperature
Ambient outdoor temperature
(WRU 400)
Relative humidity
WRU 400 degree of protection
outdoor
WRU 410
degree of protection
Transponder technology
Read range
Low power wireless technology
Signalling
Number of possible Dialock user
keys (WTC 200)
Event log
(log entries WTC 200)
RFID frequency
(ETSI EN 300 330 V2.1.1)
Transmitter field strength /
(dbṛA/m) @3m
BLE frequency
(ETSI EN 300 328 V2.2.2)
Radiated power (dBm)
Value
12 V - 24 V DC, +/- 15%
0.07 A
0.8 W
0 °C to 55 °C
–25 °C to + 70 °C
10% to 95%, not condensed
IP 40
IP 54 (only in conjunction with additional sealing components)
IP 00 (without frame)
IP 20 (with Gira frame)
IP 54 (with Siedle blind module)
ISO15693, ISO14443:
- MIFARE Classic EV1
- MIFARE DESFire EV1/EV2
- Tag-it
MIFARE Classic min. 20 mm,
MIFARE DESFire min. 10 mm,
Tag-it min. 25 mm,
• Opening an access point via low power wireless with a digital
end device and suitable app (e.g. Häfele Access Hotel)
1x red LED, 1x green LED, Piezo signal generator
≤ 10,000
Unlimited in online mode
13.56 MHz
ISO 14443 and ISO 15693;
Tag-it, MIFARE Classic EV1,
MIFARE DESFire EV1/ EV2
15.4
2400 MHz - 2483.5 MHz
0.8
73

Publicidad

loading

Este manual también es adecuado para:

Wt 410Wru 400Wru 410Wtc 200