System Code
Alarm Code
004001
System input voltage is higher than workable range (> 305 volt)
004002
System input voltage (L2 or L3) is lower than workable range (< 170 volt)
004003
System output voltage is higher than EV battery maximum voltage
004004
Request output current from EV is higher than present EVSE ability
004005
The temperature of air inlet or input contactor is higher than workable range (> 60°C)
The temperature of CCS combo charging plug is higher than workable range
004006
REMA => (> 85°C)
Phoenix => (> 75°C)
004007
The air filter need to be replaced
004008
System fan is attenuated so that need to be replaced
004009
The self test of system controller is failure
00400A
Emergency button is pressed
00400B
The user authorized by backend is failed
00400C
The user authorized by EVSE itself is failed
00400D
The temperature sensor of air inlet is broken
00400E
The temperature sensor of input contactor is broken
00400F
SPD trigger
004010
Output fuse at CCS side is broken
004011
Output fuse at CHAdeMO side is broken
004012
The temperature sensor of CCS combo charging plug is broken
004013
the temperature of air inlet or input contactor is lower than workable range (< -40°C)
004014
User stops charging
004017
System is timeout if user doesn't plug-in in 3 mnutes after authorized
004018
Charging time is up (Max: 2hr)
004019
System data storage is not enough
004020
Unknown error
004021
Charging is remotely stopped by backend office
004022
Input voltage is drop (<20V, <100ms)
004023
System L1 input voltage is lower than workable range (< 170 volt)
005001
Communication with CHAdeMO EV is broken
005005
Communication with CCS EV is broken
005006
Power rectifier is broken (SMR)
005007
Communication with CCS controller is broken
005008
Communication with auxiliary power module is broken
005009
Communication with relay control module is broken
00500C
Communication with display module is broken
00500D
Communication with RFID module is broken
00500E
Cellular module is not ready (module itself or SIM)
00500F
WiFi module is not ready
006001
Cellular connection is disconnected from APN
006002
Cellular connection is disconnected from internet
006003
Cellular connection is disconnected from backend office
006008
Ethernet connection is disconnected from internet
006009
Ethernet connection is disconnected from backend office
007001
Hardware component in power rectifier is broken
007002
Input voltage of power rectifier is higher than workable range
007003
Input voltage of power rectifier is lower than workable range
007004
Output voltage is higher than workable range of power rectifier
007006
The temperature of air inlet in power rectifier is higher than workable range (> 60°C)
007008
The temperature of PFC is higher than workable range
007009
The temperature of PFC is lower than workable range
00700A
The temperature of DCDC is higher than workable range
00700B
The temperature of DCDC is lower than workable range
00700C
The fan inside power rectifier is broken
00700D
Output oring diod is broken
00700E
Isolation test is failed
008003
5 volt for system controller is higher than workable range
008004
5 volt for other system modules is higher than workable range