Alarm Code
008005
5 volt for CAN bus is higher than workable range
008006
12 volt for other system modules is higher than workable range
008007
12 volt for EV communication is higher than workable range
008008
24 volt for relay control is higher than workable range
008009
5 volt for system controller is lower than workable range
00800A
5 volt for other system modules is lower than workable range
00800B
5 volt for CAN bus is lower than workable range
00800C
12 volt for other system modules is lower than workable range
00800D
12 volt for EV communication is lower than workable range
00800E
24 volt for relay control is lower than workable range
008010
The output current of 5 volt for system controller is higher than workable range
008011
The output current of 5 volt for other system modules is higher than workable range
008012
The output current of 5 volt for CAN bus is higher than workable range
008013
The output current of 12 volt for other system modules is higher than workable range
008014
The output current of 12 volt for EV communication is higher than workable range
008015
The output current of 24 volt for relay control is higher than workable range
008016
The temperature of 12 volt for EV communication is higher than workable range
008017
The temperature of 5 volt for other system modules is higher than workable range
008018
The temperature of 24 volt for relay control is higher than workable range
008019
The ambinet temperature of aux. power is higher than workable range
009001
GFD trigger
009003
GFD pre-warnning
009004
GFD self-test fail
00A001
Input contactor 1 is welding
00A002
Input contactor 1 is drived fault
00A003
Input contactor 2 is welding
00A004
Input contactor 2 is drived fault
00A005
The positive side of output relay for CCS charging is welding
00A006
The positive side of output relay for CCS charging is drived fault
00A007
The positive side of output relay for CHAdeMO charging is welding
00A008
The positive side of output relay for CHAdeMO charging is drived fault
00A009
The negative side of output relay for CCS charging is welding
00A00A
The negative side of output relay for CCS charging is drived fault
00A00B
The negative side of output relay for CHAdeMO charging is welding
00A00C
The negative side of output relay for CHAdeMO charging is drived fault
00B001
The firmware update of aux. power module is failure
00B002
The firmware update of relay control module is failure
00B003
The firmware update of LCM module is failure
00B004
The firmware update of CCS charging module is failure
00B005
The firmware update of CHAdeMO charging module is failure
00B006
The firmware update of power converter module is failure
00C001
PLC module for CCS charging is broken
00C002
CCS proximity is disconnected
00C003
stop charging by CCS EV
00D001
No charging permission come from CHAdeMO EV
00D002
Battery malfunction come from CHAdeMO EV
00D003
Battery incompatibility with CHAdeMO EV
00D006
Present output current is different from target current
00D007
Battery OTP come from CHAdeMO EV
00D008
Present output voltage is different from target voltage
00D009
Position shift alarm is come from CHAdeMO EV
00D00A
EV other fault is come from CHAdeMO EV
00D00B
CHAdeMO connector lock is broken
Installation and Operation Manual
Description
27
System Code