Descargar Imprimir esta página

Aritech VE700 Serie Instrucciones De Instalación página 6

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
24
26
EN: Installation Manual
Introduction
The VE735 and VE736 are PIR motion sensors. They have
a patented verified PIR technology.
WARNING!
The equipment is not earthed. Any
external circuit connected to the equipment must be
located within the same building and connected to a
protective earthing conductor.
Wire insulation of cables connected to the equipment must
conform to IEC 60332-1-2 and IEC 60332-1-3 or IEC 60332-
2-2, depending on the wire cross sectional area, or IEC
TS 60695-11-21, regardless of cross sectional area.
Alternatively, such wires must comply with UL 2556 VW-1.
Installation guidelines
The technology in this detector resists false alarm hazards.
Nevertheless avoid potential causes of instability, such as:
Direct sunlight on the detector
Heat sources within a field of view
Strong draughts onto the detector
Large animals in a field of view
6 / 50
25
Obscuring the detector's field of view with large objects,
such as furniture
Install the detector so that the expected movement of an
intruder will be across the fields of view (see example in
Figure 21, item 1). This is the direction best detected by PIR
detectors.
SB01
Mounting the detector
1.
Lift off the custom insert (Figure 1).
2.
Using a screwdriver, carefully prise open the detector
(Figure 2).
3.
Remove the interior part (Figure 3).
4.
Fix the base to the wall between 1.8 m and 3.0 m (5.9 to
9.8 ft.) from the floor. For flat mounting, use a minimum of
two screws (DIN 7998), at least one in position A and one
in position B. For corner mounting, use screws in positions
C or D (see Figures 4 and 5).
Note:
pry-off positions are shown in the warning box.
5.
Wire the detector. See Figures 7 and 8.
Note:
Electrical Code, NFPA 70 and CSA C22.1, Canadian
Electrical Code, Part I, Safety Standard for Electrical
Installations.
Figure 16 shows a single detector wiring, Figure 17 —
multiple devices connection.
6.
Select the desired jumper and DIP switch settings (see
"Setting the detector" on page 7).
7.
Replace the interior part (Figure 9).
Align the detector. See "Aligning the beam and walk
8.
testing the detector" on page 8.
9.
Remove the blinders and add the stickers, if required. See
"Selecting the coverage pattern" on page 8 and "Blocking
the curtains" on page 9.
10. Insert the insect-protection caps (Figure 10, item 1).
11. Close the cover (item 2).
12. Replace the custom insert (item 3).
CP
ST400
Not all screw positions have pry-off tamper. Non
All wiring must be provided according to National
P/N 145797999-2-ML • REV M • ISS 10JUN21

Publicidad

loading

Este manual también es adecuado para:

Ve735Ve736