Owner's Manual
1.4
Controls and Operating
SET UNIT UPRIGHT
NOTICE: Always store, transport, and use the unit in a horizontal position. If the unit is
ever placed in a vertical position, return it to the horizontal position and let it stand for
at least 30 minutes before turning it on.
POSITIONING A DEHUMIDIFIER
For best results, operate your dehumidifiers in an enclosed area. Place your
dehumidifier away from obstructions, and keep it away from anything that could
block airflow into and out of the unit. For more information about creating an
optimum drying environment, contact Legend Brands at info.LegendBrands.com.
TIP: Before installing in a crawlspace or other difficult to access location, plug in the
unit and run it for approximately half an hour to ensure proper operation.
SET UP DRAIN HOSE
The PHD 200 condensate pump connects to a 40 ft. (12 m) plastic drain hose
equipped with a quick-connect fitting for quick attachment to the unit. To set up the
hose, unwrap the entire hose and place the unattached end in a sink, drain, bucket or
outdoors – anywhere that water can drain out safely. Connect the other end of the
hose to the PHD 200. If you use a bucket or other container for water collection, check
it regularly to prevent overflows.
NOTICE: Uncoil and straighten the entire drain hose. Do not leave any part of the
hose coiled and do not place the end of the hose higher than 3 ft. (1 m) above the
bottom of the unit. Also check for kinks or other obstructions that might restrict the
flow of water. Obstructions may cause a water backup and result in overflows.
PLUG IN ELECTRICAL CORD
The PHD 200 should be plugged into a GFCI-protected 115 volt outlet rated for at
least 15 amps.
Startup display and normal display modes
When unit is first plugged in to AC power, the control panel display will briefly cycle
through a series of readouts. This is part of the unit's self-diagnosis procedure and no
user intervention is required.
PHD 200 Owner's Manual
10
© 2023 Legend Brands, Inc.