1.7
At the End of the Job
To reduce the possibility of drips when moving the unit, follow these
additional steps to ensure that all water is removed from the unit.
NOTICE: To ensure all water is removed from the dehumidifier, the unit will complete
the defrost cycle even if the unit is turned off. If the unit is unplugged during the
defrost cycle, excessive water may accumulate in the unit and may drip out when you
move the unit.
NOTICE: To ensure the condensate tank empties completely while purging, make sure
the unit is placed upright on a horizontal surface.
1. Do not turn unit off or move it until it has returned to normal operating
mode.
2. Gently rock the machine to ensure any water remaining on interior
surfaces falls into the sump area.
3. Press the PURGE key. When the purge cycle is complete, turn the unit
off.
4. Remove the external drain hose and drain it carefully.
5. Unplug the power cord.