DIODE TEST
1. Connect the black test lead to the "COM" jack and the red to the "INPUT"
jack (Note: The polarity of the red test lead is positive "+").
2. Set the range switch to "
" position.
3. Press the "Select" Button to select diode test mode, and the symbol
"
" will appear as an indicator.
4. Connect the red test lead to the anode of the diode to be tested and the
black test lead to the cathode.
5. The Digital multimeter will show the approximate forward voltage of the
diode. If the connections are reversed, "OL" will be shown on the display.
MEASURING CAPACITANCE
1. Connect the black test lead to the COM jack and the red to the "INPUT"
jack.
2. Set the range switch to "
" position
3. Press the "Select" Button to select capacitance measurement mode,
and the symbol "nF" will appear as an indicator.
4. Connect test leads across the capacitor under measure and be sure
the polarity of connection is observed.
Note: When the capacitance under measure is above 100 uF, it needs at
least 10 seconds to make readings stable.
MEASURING TEMPERATURE
1. Set the range switch to "ºC" / "ºF" range.
2. Press the "Select" Button to select "°C" or "°F" mode.
3. Insert the black (or "-") plug of the K-type thermocouple to the "COM"
jack, and the red( or "+") plug to the "INPUT" jack.
4. Carefully touch the end of the thermocouple to the object to be
measured.
5. Wait a moment, read the reading on the display.