4 TROUBLESHOOTING
The repair or replacement of any parts in the
system must be carried out only by qualified
personnel.
The repair or replacement of any parts in the system by unau-
thorized personnel will invalidate the product warranty.
The system must not be modified in any way.
The manufacturer disclaims any responsibility if the user
does not follow these instructions.
No liquid flow in circuit
Cause
No liquid in the tank.
Solution
Refill.
5 TECHNICAL SPECIFICATIONS
Power supply voltage U1 (50/60Hz)
Max. input current I1max
Cooling power (25°C)
Type of exchanger
Flow rate (QV)
Flow rate (Qvmax)
Total head (Hmax)
Pump type
Maximum rpm
IP Protection rating
Tank capacity
Dimensions (lxdxh)
Weight
Manufacturing Standards
14
WU 22
1x230V ± 15%
1.1A
1kW
H2O - Air
1.3 l/min
1.3 l/min
44 m
Centrifugal
2850 min
23S
4 l
250x700x150 mm
16 Kg.
EN 60974-2/EN 60974-10