One cleaning cycle consists of six compressed air pulses.
Automatically | at fan shutdown
After ≥30 minutes of (intermittent or continuous) operation,
one cleaning cycle takes place when the fan is off, with a delay
time of 15 seconds. If the fan starts running again within
those 15 seconds, the filter cleaning system will not be
activated.
Automatically | pressure controlled
A differential pressure switch activates the filter cleaning
system immediately when the pressure drop reaches the
threshold value during use.
Manually | by push button
To activate the filter cleaning system manually, do the
following:
•
Push and hold the FILTER CLEANING button (ref. Fig. 5.1D)
for 5 seconds.
6
MAINTENANCE
6.1
Periodic maintenance
The product has been designed to function without
problems for a long time with a minimum of
maintenance. In order to guarantee this some simple, regular
maintenance and cleaning activities are required which are
described in this chapter. If you observe the necessary caution
and carry out the maintenance at regular intervals, any
problems occurring will be detected and corrected before they
lead to a total breakdown.
WARNING
Overdue maintenance can cause fire.
The indicated maintenance intervals can vary depending on
the specific working and ambient conditions. Therefore we
recommend to thoroughly inspect the complete product once
every year beside the indicated periodic maintenance. For this
purpose contact your supplier.
Component
Action
Filter unit
Dustbin
Empty; refer to paragraph 6.3
Housing
Clean the outside with a
non-aggressive detergent
Clean the inside with an industrial
vacuum cleaner and remove dust
from the filter compartment
Check sealing material of the
door. Replace if necessary
Mains cord
Check for damage. Repair or
replace if necessary
Extraction fan
Fan housing
Check for encrusted particles.
Clean if necessary
Extraction arm
Tubes
Clean the outside with a
non-aggressive detergent
Clean the inside thoroughly
Flexible
Check for cracks or damages.
hoses
Replace if necessary
Hood
Check the movement of the hood.
If necessary, adjust the friction;
refer to paragraph 6.4
86958015
Component
Arm
movement
*) During use, you must check the level of contents in the dustbin
regularly. The emptying frequency depends on the intensity of use and
will be a matter of experience. In the initial stage, do a check on the
level of contents of the dustbin 2 times per month.
6.2
When the red LED (FILTER CLOGGED) is on, you
must replace the filter cartridge.
To replace the filter cartridge, do the following.
Fig. 6.1
•
•
•
•
•
Frequency:
every X months
X=6
X=12
*)
X
X
X
X
X
X
X
X
Fig. 6.1 Bag frame
X
Action
Check horizontal, vertical and
diagonal arm movement. If
necessary, adjust the friction;
refer to paragraph 6.4
Filter replacement
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves when you replace the filter
cartridge.
WARNING
Do not replace the filter cartridge while the fan is
running.
De-energize the unit.
Turn the rotary knob (A) in horizontal position to close the
shut-off valve.
Loosen the quick release clamp (F) and remove the dustbin
(G).
Loosen the duct clamp (D) and remove the flange (E).
If there is enough space behind the filter unit to
turn the hopper including flange 90°, it is not
necessary to remove the flange.
Loosen the 2 wing knobs (C) and release the bag frame
(B).
Frequency:
every X months
X=6
X=12
X
EN | 13