7
DD100PI
8 m
0 m
8
m
3.0 m max.
2.4 m min.
0.6 m
Note:
Pet Immune functionality has not been tested by VdS.
9
EN: Installation Sheet
Description
DD100 Series detectors are microwave verified PIR intrusion
detectors and should be installed to maximise PIR detection.
Consequently the best detection is obtained when the
expected movement of an intruder is perpendicular (or slightly
diagonal) to the detector axis, as shown in Figures 7 to 8.
The dual technology processing of this detector makes it very
resistant to false alarms. Nevertheless avoid potential causes
of false alarms, such as:
PIR hazards:
•
Direct sunlight on the detector
•
Heat sources within a field of view
•
Strong air draughts on the detector
•
Large animals in a field of view
•
Obscuring the detector field of view with large objects,
such as furniture
2 / 28
10 m
8
DD105/DD105C
1 m
0
0 m
1 m
0
3.0 m max.
2.4 m nom.
1.8 m min.
10
Microwave hazards:
•
Mounting surfaces susceptible to vibrations
•
Metal surfaces reflecting microwave energy
•
Water movement through plastic pipes
•
Heating or air-conditioning ducts pointed directly at the
detector
We recommend that you test the detector on a regular basis,
using a walk test and checking at the control panel.
WARNING!
The equipment is not earthed. Any
external circuit connected to the equipment must be
located within the same building and connected to a
protective earthing conductor.
Wire insulation of cables connected to the equipment must
conform to IEC 60332-1-2 and IEC 60332-1-3 or IEC 60332-
2-2, depending on the wire cross sectional area, or IEC TS
60695-11-21, regardless of cross-sectional area. Alternatively,
such wires must comply with UL 2556 VW-1.
Mounting instructions
Refer to Figure 1 as you follow these steps.
P/N 145919999-4 (ML) • REV N • ISS 06APR21
12 m