Descargar Imprimir esta página

Lincoln Electric OERLIKON CITOTIG 315 AC/DC Manual De Instrucciones página 15

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 93
Sequencer Functions:
The sequencer allows for the customization of the TIG
welding operation both in AC & DC- polarities. Pressing
the "Sel" button will cycle through the process graph.
Pre-Flow:
seconds gas will flow prior to arc-
start initiation
Starting Current:
starting
process.
Initial Slope:
seconds it takes the starting
current to reach normal operating
amperage.
Operating Amperage: Sets the
amperage for all welding process
permitted.
Final Slope:
seconds it takes the operating
amperage to ramp down to the
Finishing current.
Finishing Current:
finishing
process.
Post Flow:
seconds gas will flow after the arc
is terminated
English
Sets the time in
Sets the
amperage
for
the
Sets the time in
Sets the time in
Sets the
amperage
for
the
Sets the time in
Pulse Sequencer Functions:
Main Amperage Control:
The main amperage control button is intended to be a quick
selection method to adjust the main amperage setting. This
function will allow users to quickly exit the sequencer
portion of the U/I, eliminating the need to cycle through all
possible sequencer functions to adjust the main amperage
or exit the sequencer menu.
This knob is also a multi-purpose command: see the
"Operating Instruction" section for a description of how to use
this command for parameter selection.
Displays:
The right meter displays the preset welding current (A) before
welding and the actual welding current during welding, and
the left meter shown the voltage (V) at the output leads.
A flashing on both displays indicate that the value read is the
average value of the previous welding operation.
feature shown the average value for 5seconds after every
welding time.
If a remote control is connected (the Remote LED is ON), the
left meter (A) indicates the preset and the actual welding
current following the instruction explained in the "Remote
LED" description above.
The dispays are used to indicate during setting of
parameters, the name and the value of them. Also are used
for menu indication and error codes displaing.
11
Percent Peak Current:
functions sets the amount of
time the pulse waveform spends
at the peak current setting. This
function is set as a percentage
of the total time for the pulse
cycle.
Pulses-Per-Second:
Sets the
total number of pulse cycles per
second of time.
Percent Background Current:
Sets the background amperage
of
the
pulse
waveform.
Background amperage is set as
a
percentage
of
the
current.
This
peak
This
English

Publicidad

loading