the alarm in middle of the ceiling.
• If the length of the room or the hall is beyond 10 meters, you need to install multiple
alarms.
• In rooms with a combustion appliance place the detector at a horizontal distance between
1-3 meters from the CO source;
• Avoid existing air inlets or outlets and other objects on the ceiling;
• Avoid locations behind objects such as curtains and cupboards.
Don't install on these locations
• High-humidity areas such as kitchens and bathrooms.
• Next to air outlets, fans and central heating.
• Dusty, dirty areas or areas with insects.
• High-temperature and easily polluted places.
• Places with difficult access, making it difficult to operate the test function.
• Within 1.5 meters from lamps.
• Next to doors or windows.
• In the top of rooms with sloping roofs, the corner of the room or other dead-air spaces.
Mounting the detector
• Twist off the mounting bracket from the detector.
• Put the bracket on the installation position and mark the 2 screw holes.
• Drill two 5mm mounting holes and insert two plastic anchor plugs by hammer.
• Screw the mounting bracket to the ceiling or the wall.
• Attach the detector to the mounting bracket and turn clockwise to lock the device.
CAUTION
• The installation instructions must be followed strictly to avoid unsafe conditions.
• Do not paint your detector.
• The battery cannot be replaced; do not try to replace the battery.