• To replace the damaged mains cable, use
the cable type: H05V2V2-F or equivalent,
which withstands a temperature of 90 °C
or higher. Contact an Authorised Service
Centre. The connection cable may only be
replaced by a qualified electrician.
3.4 Connection diagram
N2
Blue
3.5 Assembly
If you install the hob under a hood, please
see the installation instructions of the hood
for the minimum distance between the
appliances.
min.
500mm
38
ENGLISH
380 - 415V 2N ~
220 - 240V ~
220 - 240V ~
Wiring colours
N1
Blue - Gray
min.
50mm
• The appliance works either at 50 Hz or 60
Hz and does not require any additional
action from a qualified electrician in order
to switch between frequencies.
220 - 240V 1N ~
220 - 240V ~
L2
Brown
If the appliance is installed above a drawer,
the hob ventilation can warm up the items
stored in the drawer during the cooking
process.
NL
220 - 240V ~
220 - 240V ~
220 - 240V ~
L1
Black