2) Set the power switch (F) on the back of the device to the "I" position - the
device will go into standby mode.
3) Press the ON/OFF button (i) on the control panel or the remote control to turn
on the unit. The central display will show the current ambient temperature. By
pressing the same button (i) again, you can access the rest of the device control
functions.
4) Pressing the heating function button (j) one time starts heating with low power
- the corresponding indicator light (b) will light up on the panel. Pressing the
same button again will turn on high heating power, which will be confirmed by
the additional light (c) on the control panel, i.e. both indicators (b + c) will then
be illuminated.
5) To start the timer, press the timer button (l) and then press the same button
to set the range of 0-12 hours after which the device will be turned off. After
completing this operation, the device will start counting down the set time
(the indicator "e" will light up), after which it will turn off automatically.
6) To set the target temperature, use the button to increase or decrease the
value (h or g).
IMPORTANT: if the ambient temperature is over 4
temperature, it will heat with high power. If it is lower by 2
than 4
o
C, it will heat with low power. When the set temperature in the room
is reached, the device will stop heating, only the fan will continue to work. The
heater will turn on only when the temperature in the room drops by more than
2
°
C in relation to the set temperature.
7) The air supply flap is activated by means of the air supply flap control button
(k) - its operation will cause the corresponding indicator light (d) to light up.
Use the same button to turn it off and the relevant indicator (k) turns off.
8) Turn off the device using the ON/OFF button, but remember that after turning
off the fan will be active for approx. 30-60 seconds to cool down the inside of
the device - its operation is signaled by the appropriate light (a) on the control
panel. After turning off, the device will go into standby mode.
3.4.
Cleaning and maintenance
a)
Pull the mains plug and let the unit cool down completely before cleaning,
adjusting or replacing accessories and when the unit is not in use.
Wait until the rotating parts stop.
b)
Use only non-corrosive cleaning agents for cleaning the surfaces.
c)
Do not spray the unit with a stream of water or immerse it in water.
d)
Make sure that no water enters through the ventilation openings in the casing.
e)
Clean the ventilation openings with a brush and compressed air.
f)
Use a soft, damp cloth for cleaning.