USE WOOD'S
DEHUMIDIFIER DSC95(P)
The Wood's DSC95(P) is a powerful and
sturdy dehumidifier suitable for crawl spaces,
basements, laundry rooms, and large areas.
Any reference to a pump throughout this
manual correlates to the DSC95P only, as the
DSC95 does not contain one.
Features:
• Automatic defrost for use in lower
temperatures, down to 2°C.
• Automatic pump (DSC95P only) for water
drainage to a sewer.
• Duct connection for better distribution of the
dried air.
• Automatic restart with memory function after a
power cut.
• Easy to use controls.
• Efficient air filter.
WORKINGS OF YOUR DEHUMIDIFIER
The Wood's DSC95(P) is a compressor-driven
dehumidifier. As the air is circulated through the
room and drawn through the dehumidifier by the
fan, the air passes over the cooling/drying battery.
The coils cool down the air led through, which
causes its water content to condensate on the coils.
The condensate is collected in a tray underneath
the cooling battery, led to the pump (DSC95P only),
and drained via an external hose. The remaining
dry air is exhausted throughout the room.
As the dehumidifier condensates the water
vapour, heat energy is released. That is why a
compressor dehumidifier will exhaust warm, dry
air, which is extra beneficial for drying clothes,
laundry, wood, etc.
A compressor dehumidifier is the most energy-
efficient way to remove excess moisture and foul
odour. To achieve safe and reliable protection against
mould and moisture damage, it is recommended to
keep the relative humidity level around 50%.
PRODUCT OVERVIEW
See pages 2–3 for image product overview.
DEHUMIDIFIER DSC95(P)
A
1.
Control panel
2.
Nose clamp (DSC95P only)
(for external drain hose, hose not included)
3.
Hose nozzle (DSC95P only)
4.
Modular cable (control panel)
5.
Air exhaust bracket
6.
Air exhaust hose
B1
DRAIN HOSE ASSEMBLY
DSC95P (WITH PUMP)
DRAIN HOSE ASSEMBLY
B2
DSC95 (WITHOUT PUMP)
C
PUMP+FILTER (DSC95P ONLY)
1.
Garden hose nozzle
2.
Pump filter
3.
Drainage pump
AIR FILTER
D
E
CONTROL PANEL
CONTROL PANEL FUNCTION
DESCRIPTION
The Wood's DSC95(P) are equipped with an
intuitive wired remote-control panel for simple
and convenient use. If the 2 m wire supplied with
the unit is too short, it can be replaced by an
RJ11/RJ12 modular cable with male connectors
at both ends. Please note that the length of the
cable should not exceed 10 m.
Note that the control panel powers down to
idle mode 20 seconds after connection of mains
voltage or after the last input. It is revived by
touching the area where the function keys are
located. All keystrokes are confirmed with a beep.
FUNCTION KEYS
1.
ON/OFF: Switches the dehumidifier on and
off. In off mode, the energy consumption
equals 0.5 W.
2.
Setting of the desired humidity: Only
active in program modes "Normal" and
"Fan".
A desired humidity can be set between 35
- 75% in steps of 1 percentage point. The
set value is first displayed fixed and then
flashing before the actual value reappears.
3.
Mode selection: Selection of the operating
program; refer to points 12. - 14.
4.
Fan speed: The fan's speed in "Normal"
and "Fan" mode may be set at low or high
speed. Switching between the speeds
takes place with a few seconds delay.
ALARMS / INFORMATION
5.
Defrost: If necessary, the cooling circuit
is defrosted automatically, whereby the
compressor is switched off, and only the
fan is in operation. The symbol goes out
when the dehumidification process is
restarted.
6.
Too high ambient temperature: If the
ambient temperature exceeds 35° C, the
dehumidification process shuts off and
resumes automatically when the ambient
temperature falls below 35° C. The symbol
is lit as long as the temperature is 35° C or
higher.
7.
Low room temperature: If the ambient
temperature falls below 2° C, the
dehumidification process shuts off and
resumes automatically when the ambient
temperature rises above 2° C. The symbol
is lit as long as the temperature is 2° C or
lower.
8.
Pump malfunction (DSC95P only): If a
pump malfunction occurs, an audible signal
is activated for 20 seconds, and the symbol
is lit. Refer to the "Problem/Remedy" table.
9.
Room temperature: Displays the detected
ambient temperature.
10.
Fan speed: Fan and dashes indicate high
speed, and only the fan indicates low
speed.
11.
Relative humidity: Shows current and
desired target values. The latter is in
connection with target value setting.
OPERATING MODES
12.
Fan Mode (FAN) – Continuous air
circulation even if the humidity target value
is reached.
13.
Comfort mode (EASY) - The dehumidifier
aims for 50% relative humidity with the fan
set to low speed. When the target value is
reached, the compressor and fan shut off
Product Description
and restarts if the humidity rises above 50%.
14.
Normal Mode (NORMAL) – Used to set the
target value for humidity and fan speed
manually. When the set target value is
reached, the compressor and fan shut off
and restarts if the humidity rises above the
target value.
15.
Lock function - Used to prevent the
settings from unintentionally being
changed. The lock function is activated
by simultaneously operating the FAN and
MODE keys for 3 seconds. Disabling the
lock function is done in the same way.
GB
05