TECHNICAL DATA
Max. working area
Airflow step 1
Airflow step 2
Dehumidifying at 20° C and 70% r.h.
Dehumidifying at 30° C and 80% r.h.
Power at 20° C and 70% r.h.
Power consumption at 20˚C and 70% r.h.
Refrigerant
Charge
Voltage
Frequency
Fuse
IP Code
Dimensions in mm (L x W x H)
Technical changes and improvements may occur. All values are
approximate and may vary depending on external circumstances
such as temperature, ventilation and humidity.
PROBLEM
REMEDY
• Ensure that the dehumidifier is connected to the power socket and that the fuse has not blown.
The dehumidifier does
• Check that the humidity value in the machine's control panel is displayed by "waking up" the panel.
not start
The dehumidifier shall start within 5 minutes if this value exceeds the set value.
• Make sure the fan wheel is spinning.
• Make sure that the air can flow freely through the dehumidifier. The air exhaust and air filter must be clean, and the
dehumidifier must be positioned at least 25 cm from any wall.
The dehumidifier does
not dehumidify
• Listen if the compressor is running, but keep in mind that the dehumidifier may be defrosting, causing the compressor to
stop. Start by waiting for about 30 minutes.
• Check that a thick layer of ice does not form on the cooling circuit behind the filter.
Abnormal noise
• Check the levelling of the unit and make sure that it rests on all buffers.
• Check that no dirt or debris is deposited on the drip tray underneath the cooling coils; clean if necessary.
No condensate water
collected
• Check that the temperature is above 2° C or below 35° C.
The dehumidifier is
• The pump filter requires cleaning. Disconnect the unit, detach the pump and clean the filter insert.
flooding (DCS95P only)
Re-attach the pump and connect the unit.
• If E2 is shown in the display, the humidity sensor may be defective. Try unplugging the power cord, wait 10 seconds and
Error code E2
reconnect it. If the error code persists, contact your dealer.
Error code E4 (DCS95P
• The pump is malfunctioning. Disconnect the unit, detach the pump and clean the filter insert. Re-attach the pump and
only)
connect the unit. If the error code persists, contact your dealer.
If you have a problem with your dehumidifier, refer to the troubleshooting guide. If none of the above works, contact your dealer to get your dehumidifier serviced.
DSC95(P)
230 m2
200 m3/h
300 m3/h
23 L/24h
42 L/24h
500 W
11 kWh/24 h
R290
150 g
220–240V
50 Hz
10A
IPX1
622 x 360 x 450
This marking indicates that this product should not be disposed with other household wastes throughout the UK
and the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal,
recycle it responsibly to promote the sustainable reuse of material resources. To return your us device, please
use the return and collection systems or contact the retailer where the product was purchased. They can take
this product for environmental safe recycling.
Operating Instructions
6
YEARS
WARRANTY
GB
07

Publicidad

loading

Este manual también es adecuado para:

Dsc95p