3. TECHNICAL SPECIFICATIONS
Accuracy is guaranteed for 1 year at 23 ºC 5 ºC less than 80% RH
DC VOLTAGE
Range
200 mV
2000 mV
20 V
200 V
1 000 V
Overload protection: 220 V RMS AC, for 200 mV range and 1 000 V CD
or 750 V rms for all ranges
AC VOLTAGE
Range
200 V
750 V
Response: Average response, gauged in rms of sine-wave
Frequency range: 45 Hz ~ 450 Hz
Overload protection: 1 000 V DC or 750 V RMS for all ranges
AUDIBLE CONTINUITY
Range
Overload protection: 15 seconds maximum 220 V RMS
DIRECT CURRENT DC
Range
200 µA
2 000 µA
20 mA
200 mA
10 A
Resolution
100 µV
1 mV
10 mV
100 mV
1 V
Resolution
100 mV
1 V
Description
Built-in vibrator that vibrates if resistance
is less than 30 20
Resolution
100 nA
1 µA
10 µA
100 µA
10 mA
Accuracy
(0.5% de rdg + 3 D)
(0.8% de rdg + 5 D)
(1 % de rdg + 5 D)
Accuracy
(2 % de rdg + 10 D)
Accuracy
(1.8% de rdg + 2 D)
(2 % de rdg + 2 D)
(2 % de rdg + 10 D)