4.3 Resharpening the Shearing Blades

Only work with sharp shearing blades. Replace blunt blades or those with missing teeth.
Proper resharpening can only be done with a special machine and by a trained technician
contactable through your service centre.

4.4 Cleaning the Air Filter

The air filter element is found on the underside of the motor section of the machine. The air
filter element can be removed from the machine for cleaning. Regularly cleaning the element
with a dry brush is essential. When cleaning the air filter, take care that no foreign bodies
get into the machine.
Illustr. 12
The machine must never be operated without the air filter element!

4.5 Changing the Shearing Head (Option)

To change the shearing head from "Sheep" to "Cattle" or vice-versa, loosen both head
screws. Remove one head and fit the other (Grease cog wheel, Illustration 1, Item 8, if
necessary). Re-tighten both screws.
Illustr. 13

4.6 Storing the Shearing Machine

Only store the shearing machine in a dry place and in the case supplied. Do not switch on
the machine if you suspect any liquid has got into it. There is then a risk of an electric shock
or short circuit. Hand the shearing machine into a service centre.
Make it a habit to store the machine between use, stor it well-cleaned, oiled and with tension
slackened off, in its storage case, in a clean, dry place, out of the reach of children.
Illustr. 14

5 Repairs

This product has been developed and assembled using the best individual components
available. It is designed to give longevity and high performance. If spare parts are used
during the life of this product, please ensure that they are genuine Heiniger parts. Failure to
use genuine Heiniger spares may reduce the performance of this precision engineered
product and will void any warranty claim.

5.1 Introduction

Actions to be taken to rectify malfunctions are indicated in the "Rectification" column of the
malfunction lists. Those rectification notes printed on a dark background may only be carried
out by an authorised service centre.
Details of authorised service centres are to be found at the end in the "Contact Addresses"
section.

5.2 Malfunction Lists

Contact an authorised service centre in the event of malfunctions not contained in these
instructions.