TECHNICAL SPECIFICATIONS:
Part Number
Type
Input Voltage Range
Input Frequency
Output for each channel
Size (L*W*H) in mm
Weight
Approvals
CHARGING INSTRUCTIONS:
 Check the Battery Electrolyte level (Not required on sealed & Maintenance Free Batteries).
If necessary, remove the vent caps and add distilled water so the levels are halfway between the
upper and lower fill lines.
 If the Battery is out of the vehicle:
o Connect the Red lead from the charger to the positive (+) battery terminal.
o Connect the Black lead from the charger to the negative (-) battery terminal.
 If Battery is still in the vehicle, determine if the vehicle is positively or negatively earthed.
o If Negatively Earthed (Most Common) – FIRST Connect the Red (+) battery charger
lead to the positive (+) Battery post and then connect the Black (-) battery charger
lead to the vehicle's chassis and away from the fuel line.
o If Positively Earthed – FIRST Connect the Black (-) battery charger lead to the
Negative (-) battery post and then connect the Red (+) battery charger lead to the
Vehicle's chassis and far away from the fuel line.
STEP 3 - Connect the battery charger to Mains Power (230Vac)
 Connect the battery charger to a 230VAC Mains Powered socket.
 Turn on the Mains Power.
 The Charger will automatically start when AC power is connected and switched on.
STEP 1 - Pre Charge Check & Electrolyte Level Check
STEP 2 - Connecting the Battery charger to your Battery
BK15
Smart
100-240Vac
50/60Hz
1500mA @ 12V
328*157*44
2.6Kg
CE