Descargar Imprimir esta página

3D Systems SLA 750 Serie Guia Del Usuario página 99

Publicidad

8/18/22, 10:52 AM
Solución de problemas
Build Stops with no Warning.
Y Motor Stopping during Recoater Calibration. 
Displacer stalls while homing elevator.
Resuming job after reboot won't Move to Drain
or Move to O oad. 
Build time not displaying or updating during a
build.  
Course leveling doesn't detect/prompt the
need for material in rare edge cases.
X, Y, or Z Following errors during a build.
Leveling timeouts during a build.  
Build Failure occurring mid-build.
Failed to nd start position. 
Laser power too low. 
Unable to manually turn on Laser and check
power.  
UI randomly closing on machines.
Manual level doesn't trigger the Add Material
Prompt pop up. 
No error shown on the UI for pro ling failure at
the Start of or during a build. 
es.infocenter.3dsystems.com/sla-750-series/print/book/export/html/526
Summary
Guía del usuario
Recovery
Power Cycle + Resume Print feature. 
Power Cycle the System. This is a known
issue with using the Home Function before
calibration. Please use the manual controls to
move the recoater to the home position. 
Power Cycle the System. 
User must home the elevator and then
manually move the elevator if power is lost
during build.
Power Cycle the System. 
Manually Coarse leveling the vat does not
detect the need for material, but the leveling
routine fails at the start of a build because the
material is low. This is a known edge case. 
Power Cycle the System + Resume Print
feature. 
Power Cycle the System + Resume Print
feature. 
Power Cycle the System + Resume Print
feature. 
Power Cycle the System
Try starting the print again. There is an edge
case where the laser doesn't warm up in time
for the build to start properly. If the issue still
occurs after restarting the print, Power Cycle
the System.
Power Cycle the System. If the issue persists,
please contact Technical Support. 
Known issue. Please Power Cycle the System
+ Resume Print feature. 
Build Start will trigger bottle ll. Know issue
that will be xed in future rmware release. 
Power Cycle the System. 