switching top and rear venting
VENTED
MODE
TO CONVERT THE UNIT FROM TOP EXHAUST TO REAR EXHAUST
FOLLOW THESE SIMPLE STEPS:
1. Unplug the quick disconnect coupling that supplies power to the motor.
2. Remove the twelve (12) screws that fasten the blower assembly and filler
plate to the hood.
180°
Y
3. Remove the blower assembly and filler plate, invert 180° as shown and
fasten in place using the twelve (12) screws previously removed.
4. Reconnect the quick disconnect plug.
- 13 -