Descargar Imprimir esta página

Futurelight PRH-540-2 Manual Del Usuario página 42

Publicidad

Idiomas disponibles

Idiomas disponibles

b) Editing via the external controller
• Call up the first scene in your controller now.
• Select "SC01" by pressing [UP] or [DN].
• Press [MODE/ENTER], the display shows "SC01".
• Press [MODE/ENTER], the display shows "C-01".
• Select "CNIN" by pressing [UP] or [DN].
• Press [MODE/ENTER], the display shows "OFF".
• Press [UP], the display shows "ON".
• Press [MODE/ENTER], the display shows "SC02". You successfully downloaded the first scene.
• Adjust the Step-time as described above.
• Call up the second scene in your controller now.
• Repeat steps 5-11 until all desired scenes are downloaded.
• Press [EXIT] to exit. The number of steps can be defined under "STEP" and the scenes can be called up
under "RUN"
Error Messages
When you turn on the device, it will make a reset first. The display may show "XXEr" while there are
problems with one channel. "XX" stands for the channels equipped with a testing sensor.
When the display shows "01Er", it means there is some error in channel 1.
01Er:
(PAN movement error) This message will appear after the reset of the device if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main
PCB). The plate is not located in the default position after the reset.
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The cooling-fans should be cleaned monthly.
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
Do not operate this device with opened cover!
42/83
51837615_V_1_1.DOC

Publicidad

loading