Wiring section from the regulator to the battery:
Table for Copper wires (Cu).
Model
Bornay 13+
Bornay 13+
Bornay 13+
Bornay 25.2+ *
Bornay 25.2+
Bornay 25.2+
Bornay 25.3+ *
Bornay 25.3+ **
Bornay 25.3+
Wires longer than 10m are not recommended for the connection between the
regulator and the batteries. If, for some reason, it is required to install longer cables,
it must be approved by Bornay.
Batería (V)
0-5m
(mm
12
50
24
35
48
25
12
50
24
50
48
35
12
50
24
50
48
50
0-5m
5m-10m
2
)
(AWG)
(mm
1/0
95
2
70
3
50
1/0
120
1/0
95
2
70
1/0
120
1/0
95
1/0
95
5m-10m
2
)
(AWG)
4/0
2/0
1/0
5/0
4/0
2/0
5/0
4/0
4/0