DUCTING TO HVAC SYSTEMS (Closet Installations)
9
1. Recommended Closet Installation
Due to space limitations, a closet installation may require additional considerations. Locate the dehumidifier under
or next to the HVAC system as space allows. A passive vent or louver door is required to allow air to be pulled in
from the living space.
•
No inlet duct is required. Air is pulled through the passive vent or louver door from the living space. Where
outlet space is restricted, the outlet duct collar is optional.
•
Install an insulated duct from outside to the 6" collar of the Santa Fe Ultra Series Dehumidifier to provide
outdoor air ventilation (optional).
•
Control should be located remotely from the dehumidifier and placed in a central location.
WARNING!
WHEN INSTALLING THE DEHUMIDIFIER AS PART OF A COMBUSTION TYPE HVAC SYSTEM (GAS, OIL, PROPANE,
ETC.), FOLLOW ALL LOCAL AND NATIONAL BUILDING AND SAFETY CODES.
a. Central Return to HVAC Supply
Duct the supply of the Ultra Series
Dehumidifier to the supply of the
existing HVAC system with a backdraft
damper.
16
Santa Fe ULTRA120V Installation & Operation Instructions
Backdraft
Damper
HVAC
Return
Ultra Series
Supply
HVAC
Supply
Ultra Series
Return
Motorized
Damper
Optional Outdoor
Air Intake
Duct Cover
Plate
Santa-Fe-Products.com | 800.533.7533