DEHUMIDIFIER SET UP
4
2. Location Considerations
•
Allow sufficient clearance to handle the unit's overall dimensions as well as the necessary return and
supply ductwork to the unit.
•
Allow sufficient clearance for filter removal and to prevent airflow obstruction.
•
Electrical service access will require the removal of the front panel. Allow sufficient clearance on this side of
the unit.
•
Locate the dehumidifier in an area where the cord's length (9') easily reaches a 115 VAC electrical outlet
with a minimum of a 15 Amp circuit capacity.
•
Locate the dehumidifier in an area where field wiring the control (low voltage) to the unit will be possible.
•
It is recommended that a backdraft damper be used in the discharge duct of the Santa Fe Ultra120V,
especially when connecting to the supply ducting system. The backdraft damper prevents supply air from
counter flowing through the Santa Fe Ultra120V when it is not operating. The dehumidifier's location should
be chosen to allow installation of this accessory if necessary.
•
Do not hang the Santa Fe Ultra120V from its cabinet.
•
Allow for proper routing and drainage of needed drain pipes.
6
Santa Fe ULTRA120V Installation & Operation Instructions
6" Optional Outdoor Air Intake
8" Return Air Duct
8" Supply Air Duct #1
8" Supply Air Duct #2 (Optional)
8" Duct Cover (Optional)
Front View
Santa-Fe-Products.com | 800.533.7533
7
9
6