6. OPERATION
During operation
• The motor is protected against overheating by an integrated thermostat. In the event
of overheating, the thermostat will automatically switch off the pump. The pump will
automatically restart after it has cooled down.
• Depending on the suction height and the amount of air in the intake line, priming can take
anywhere between 1 to 5 minutes. If it takes longer than this, the pump should be refilled
with water. Always remove the plug from the socket before refilling!
• The pump will switch off when the cut-out pressure of 5.5 Bar is reached.
• After a loss of pressure due to water consumption, the pump will switch on again automatically
(cut-on pressure approx. 1.5 Bar)
• If at any time after use the pump to be removed, it must always be refilled with water
whenever it is powered up and used again.
7. MAINTENANCE
DANGER! Risk of injury due to electric shock.
Warning! Always remove the plug from the socket before servicing,
cleaning or storage.
Servicing
If the pump becomes clogged, connect the discharge line to the water line and disconnect
the suction hose. Open the water line then switch on the pump several times for approx. two
seconds. This should solve most clog-related problems.
Storage
• Open the water drain screw
• Store the pump so that it is protected from frost.
• After long periods of stoppage make sure the rotor turns correctly by briefly switching the
pump on and off.
EN
20151209 SPECIFICATIONS 1300 JET AUTO 5I-3.indd 128
, empty the pump completely and allow it to dry.
4
128