Descargar Imprimir esta página

Dea NET230N Instrucciones De Uso Y Advertencias página 49

Ocultar thumbs Ver también para NET230N:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 131
7 How to adjust the limit switche
1. Scroll down the parameters untill you visualize P001;
2. confi rm by pressing the
3. by pressing
(OPEN) and
leaf in the opening position and adjust the limit
switch cam so that it pushes the microswitch in that
point;
Repeat adjusting the closing limit switch.
4. Confi rm by pressing the
P001).
WARNING If the Operator 2 is present, repeat the previous settings using P002.
8 Motor stroke learning
1. Scroll down the parameters with
2. Access the parameter by pressing the
3. When "
" fl ashes, continue pressing the
4. Release the
key when "
the power supply, inverse the operator cables and repeat the operation);
5. Wait for the door (or doors in case of using 2 motors) searches and stops on the opening stop and then on the closing stop.
If you want to anticipate the stopping strokes in opening, you can manually intervene by giving an impulse to "Start" button (or
pressing the "OK" on the control panel) simulating the stroke.
Warning: For operators without encoder, the stroke is not detected, so it MUST be simulated both while opening and while closing (for
both oeprators) by pressing the
6. Once the procedure is ended, the display will show "- - - - ".
Type 01 and
WARNING (only
then check the manual release to make sure it is working properly. If it's to "hard" increase the value of P057 of 1 or more.
9 Transmitters learning
9.1 Transmitters coding selection
1. Scroll down the parameters with
P027;
2. Confi rm by pressing on the
3. Select the type of transmitter by scrolling
- d000=fi x rolling-code (suggested);
- d001=complete rolling-code;
- d002=dip-switch;
- d003=DART;
4. Confi rm by pressing on the
Warning: If you need to vary the type of encoding, and only if other remo-
tes with different encoding are memorized, you need to erase memory
(P004) AFTER you have set the new encoding.
key;
(CLOSE), move the
key (display shows again
and
keys until you visualise P003;
key;
key;
" stops fl ashing; Start the learning procedure with operator 1 opening (if it starts closing, disconnect
key.
Type 03) Once you have executed the learning stroke, operate a complete cycle (opening/closing) and
and
keys until you visualise
key;
and
keys:
key (display shows again P027).
EN-15

Publicidad

loading