4 Downloading/uploading data memory
4.1 Downloading data to an external memory unit (DOWNLOAD)
1. Scroll down the parameters with
2. Press the
key, the display visualizes the word "
3. Press the
again and continue pressing it for 5 sec (if you release it before this period, the procedure is stopped);
4. Release the
key as soon as the word "
All the control panel confi gurations (TYPE, parameters, remotes, operators stroke, etc..) are saved in the external memory unit;
Warning: If there is any data in the external memory, during the memory download they will be overwritten.
5. At the end of the operation display returns to P011.
4.2 Uploading data from an external memory unit (UPLOAD)
1. Scroll down the parameters with
2. Press the
key, the display visualizes the word "
3. Press the
again and continue pressing for 5 sec (if you release it before this period, the procedure is stopped);
4. Release the
key as soon as the word "
All the control panel confi gurations (TYPE, parameters, remotes, operators stroke, etc..) contained in the external memory unit are
uploaded in the connected control panel;
5. At the end of the operation display returns to P012.
WARNING If you are not connected to any external storage units or if the connecting cable is disconnected during the data transfer
operation, the display will visualize
Refer to the instruction of the external memory card to restore the operation of the control panel.
5
Inputs confi guration
Where the installation requires different commands and / or additional to
the standard ones described by plan, you can confi gure each input for the
operation desired (eg START, PHOTOS, STOP, etc ...).
1. Scroll down the parameters with the
to the desired one:
● P017=for INPUT 1;
● P018=for INPUT 2;
● P019=for INPUT 3;
● P020=for INPUT 4;
● P021=for INPUT 5;
● P022=for INPUT 6;
2. Confi rm by pressing on the
P018);
3. Scroll down with the
the desired operation (refer to table "Input Confi guration parameters" on
page EN-22);
4. Confi rm by pressing on the
5. Execute the new connection to the input just reconfi gured.
6
Programming complete
WARNING At the end of the programming procedure, use the buttons
is now ready again for new manoeuvres.
and
keys until you visualize P011;
" stops fl ashing;
and
keys until you visualize P012;
" stops fl ashing;
, then the control unit is entirely reset and the display shows the word "TYPE" fl ashing.
and
to see that corresponding
key to get access to the parameter (eg.
and
, keys to set the value corresponding to
key (display shows again P018).
" fl ashing;
" fl ashing;
and
until the appearance of the symbol "- - - - ", the operator
EN-19