Upon receiving a code, the receiver checks whether it is in its memory, activating the corresponding relay R1 and/or R2. The relay
activation mode is selected in either impulse or ON/OFF using the Imp/Bies jumper (only with the relay 2). For adjustment of relay
1, see manual of the programming tool.
The receiver checks that all the programmed bands are working properly. If a band is activated or if there is an error in its
operation, the receiver activates the appropiated B1 or B2 output relay and the appropiated B1 or B2 light indicator turns on.
PROGRAMMING
MANUAL PROGRAMMING OF MOTION TRANSMITTERS
Press the receiver programming button for 1 sec. and an acoustic signal will be heard. The receiver will enter standard
programming (see table). If the receiver programming button is held pressed down, the receiver Hill enter special
programming, cyclically passing from one configuration to the next. Once the programming configuration for the
transmitter to be registered has been chosen, send the code to be programmed by pressing the transmitter. Every time
a transmitter is programmed, the receiver will issue an acoustic signal for 0.5 sec.
Configuration of transmitter programming in the receiver.
Standard Programming (default option,
the receiver is always configured on pluri-channel)
The relays are activated 1st relay by channel 1
and 2nd relay by channel 2 (3rd relay by channel 1
and 4th relay by channel 2)
Special programming
By pressing any transmitter channel,
relay 1 on the receiver will be activated
By pressing any transmitter channel,
relay 2 on the receiver will be activated
By pressing any transmitter channel, the two relays
will be activated at the same time*
*If working in ON/OFF activation mode, relay 1 will act as impulse and relay 2 as ON/OFF. Therefore, on the first press relay 1 will close and open the
contact and relay 2 will only close. On the second, relay 1 will close and open the contact and relay 2 will open.
N.B.: Each transmitter can be configured independently on the receiver.
MANUAL PROGRAMMING OF RADIOBAND TRANSMITTERS
Makes it possible to store 6 RADIOBAND transmitters (3 Relay B1 and 3 on Relay B2).
Press the receiver programming PROG button for 1s; a sound signal will be heard. The receiver will enter safety band
closing programming mode (BSC). If the programming button is kept pressed, the receiver will enter safety band opening
programming mode (BSO), moving cyclically from one really to another. Once the programming relay has been chosen for
the transmitter you want to start using, send the programming code by pressing the RADIOBAND transmitter. Every time a
transmitter is programmed, the receiver will emit a sound signal for 0.5s.
Note: For proper operation of the system, the transmitter must be programmed into one receiver only.
In both programming modes, after 10 seconds without programming, the receiver will exit programming mode, issuing two
acoustic signals of 1 sec. If upon programming a transmitter the receiver memory is full, it will issue 7 acoustic signals of 0.5
sec. and exit programming.
RADIOBAND transmitter replacement
In case you need to replace a RADIOBAND transmitter, it is necessary to reset the system (see TOTAL RESET on next page) and
reprogram all RADIOBAND transmitters used in the installation.
RBMOT30 / RBMOT500
In programation
Relay B1 Led
Turned on. It indicates the channel to program.
Relay B2 Led
Turned on. It indicates the channel to program.
Led R1
Flashing
ON
OFF
ON
17
Led R2
Flashing
OFF
ON
ON

Publicidad