TOTAL RESET
In programming mode (PROG RADIO or PROG RBAND, depending the memory which wants to be erased), the programming
button is held down and the "MR" reset jumper is bridged for 3 secs. The receiver will issue 10 short acoustic warning signals
followed by others at a faster pace to indicate that the operation has been successful. The receiver is now in programming
mode.
After 10 seconds without programming or quickly pressing the programming button, the receiver will exit programming mode,
issuing two acoustic signals of 1 sec.
OTHER RADIOBAND1G FUNCTIONS
POLARIZED AUTO-TEST
Check the auto-test output on the control panel, in standby, to see whether the voltage is 0V (inverted test input) or
12/24V AC/DC (positive polarity). The auto-test signal of the panel must remain at its maximum for 2 seconds.
Connection to an
equipment with autotest
Connection to an
equipment without
autotest**
* N.B.: Only connect the auto-test output to be used.
** Where the auto-test is not used, the system is not checked at the start of the operation, which means that security
normative EN 12453 regarding the use of motorised garage doors is, in some cases, not complied with.
SYSTEM CHECK
This function has to be used to check the operation and range of all the devices once the installation has been carried
out.
Press the receiver‟s CHECK button for at least 1 second to enter check mode. The indicator light will come on and four
beeps will be heard.
Perform a complete door opening and closing manoeuvre. During the system check a beep will be heard every 1,5
seconds.
CORRECT OPERATION OF THE SYSTEM
If no other acoustic signal is heard on completing the manoeuvre, the system is operating correctly. Either press the
CHECK button again or wait 5 minutes and the RADIOBAND receiver will exit checking automatically, indicating with two
beeps that the check has been correct. The check indicator light will go out.
DETECTION OF BAND FAILURE
If the communication with a RADIOBAND transmitter fails during checking, or the communication is deficient (for
instance, too many communication retries or poor coverage), the RADIOBAND receiver emits three consecutive beeps,
indicating that an error has occurred. Halt the door manoeuvre and press the safety bands installed to detect what has
failed.
If a single beep is heard on pressing a band, this means that the band is correct.
If three consecutive beeps are heard on pressing the band, this means that the band has failed.
In this event, it is recommended changing the orientation of the transmitting-receiving aerials to ensure the desired range.
On exiting check mode, seven consecutive beeps will be heard and the indicator light will flash continuously.
Perform another system check until the result is correct.
SIGNAL COVERAGE
After pressing one of the installed bands, continuous flashes, ranging from 1 to 5, indicate the signal coverage for this
band at the time it was pressed.
RBMOT30 / RBMOT500
Autotest
Autotest
output in
output
standby
activated
0V
12/24V
12/24V
0V
---
---
Polarity type
Jumper ATEST
POL
Positive
OFF
inverted
ON
---
OFF
18
ATEST1
ATEST2
Connected*
Connected*
Connected*
Connected*
No
No
connected
connected

Publicidad