2. Plug the battery charging cable into the DC
receptacle of the generator.
3. Connect the red (+) battery charger lead to the
red (+) battery terminal.
4. Connect the black (–) battery charger lead to
the black (–) battery terminal.
5. Start the generator.
NOTE:
When the battery circuit is in use the AC capacity
is reduced by 60 watts. Make sure the combined
load is within the rated limits.
WARNING
Do not continue to charge a battery that becomes
hot or is fully charged.
DC CIRCUIT PROTECTOR
A DC circuit protector has been provided to
protect the circuit from overloads. If an overload
occurs, the circuit protector will trip. The circuit
protector may be reset by pushing the button of
the protector.
Charging a large capacity battery or a totally
discharged battery may cause the DC breaker to
turn off. In these cases, a separate battery charger
unit connected to an AC power source is
recommended instead of the DC receptacle on
the generator.
Stopping the Engine
1. Turn off and remove entire electrical loads.
Never start or stop the generator with
electrical devices plugged in or turned on.
Let the generator run at no-load for two
minutes to stabilize internal temperatures
of the engine and generator.
English
All manuals and user guides at all-guides.com
2. Press the engine switch to the "OFF"(O) position.
Do not leave the generator until it has
completely stopped.
3. Turn the fuel valve to the "OFF"(O) position.
4. Turn the fuel cap vent lever to the "O "(O) position.
If a cover is used, do not install until unit has cooled.
WARNING
Fuel and its vapors are extremely flammable and
explosive which could cause burns, fire or
explosion resulting in death, serious injury
and/or property damage.
DO NOT stop engine by moving choke control
to "START" position.
Important: Always ensure that the Fuel Valve
and the Engine Switch are in the "OFF" position
when the engine is not in use.
If the engine will not be used for a period of two
weeks or longer, please see the Storage section
for proper engine and fuel storage.
Page 16
FF