12
DC Circuit Breaker - The circuit protector may be reset
by pushing the button of the protector.
Parallel Operation Outlets - These outlets are used
13
for connecting two FIRMAN inverter generators for
parallel operation. A FIRMAN parallel kit(optional
equipment) is required for parallel operation.
14
12V DC outlet – 8.3 Amp of DC current may be drawn
from this receptacle.
Use this outlet to charge 12V automotive type
batteries ONLY. See 12V DC outlet (Battery
Charger) section.
Remote Start Program Button - Use this button
15
along with the remote control to program the
generator to be started remotely.
16
Remote Start Indicator light - The light will light
or flash depending on the status of the remote start
system.
Ground Terminal – Consult an electrician for local
17
grounding regulations.
18
Outlet Cover - Protect the receptacles from dust
and debris.
19
Fuel Valve Knob
Choke Button
20
21
Recoil Stater
12V DC Battery Charger Port - Plug the 120 Volt
22
AC charger into this port to charge the generator
battery.
English
Remote Control Programming
Before the generator can be started , an initial
start-up procedure must be performed so the
generator and the remote control recognize
each other.
NOTE:
YOUR REMOTE CONTROL IS ALREADY PROGRAMMED IN
FACTORY FOR YOUR CONVENIENCE. AND IT IS READY TO
START THE GENERATOR.
If the remote control is replaced then you will
need to go through following procedure with
new remote control.
1. Flip the engine switch to the "RUN"(l) position.
2. Push the battery power restore switch for about
3 seconds and then release.
3. Press the program button and hold on, the remote
indicator light will light up for about 3 seconds and
then be off. After that, release the program button.
Erase the remote program successfully.
Program
Button
Indicator
Light
4. Push the program button on the control panel
once and the remote indicator light will light up.
Page 09
Customer Service: 1-844-FIRMAN1